| Availability: | |
|---|---|
| Quantity: | |
SBWZ
Jiechuang
The Pt100 Integrated Temperature Transmitter with Mineral-Insulated Probe is designed for industrial process temperature measurement. It combines a Pt100 resistance temperature detector (RTD) with a built-in temperature transmitter in one compact assembly.
The transmitter converts the Pt100 resistance signal into a standard 4–20 mA output for compatible PLC, DCS, and industrial control systems. The mineral-insulated probe provides a compact sensing structure for industrial installation. A separate thermowell can provide additional mechanical protection when the assembly is designed for use with the specified process connection.
The SBWZ series is intended for temperature monitoring in industrial pipelines, tanks, process equipment, and other compatible installations. Measuring range, probe dimensions, connection details, output configuration, communication functions, and enclosure protection should be confirmed for the selected model before ordering.
Used for process temperature monitoring where the sensor materials and assembly design are compatible with the process medium and operating conditions.
Provides a temperature measurement point for compatible pipeline installations. Confirm the connection, pressure conditions, and thermowell design before use.
Can be considered for temperature monitoring in compatible heating equipment. Verify the required temperature range and assembly limitations.
Supports process temperature measurement in compatible water treatment systems. Select wetted materials according to water chemistry and treatment additives.
Provides a 4–20 mA temperature signal to compatible monitoring and control equipment.
Can be used for temperature measurement where the installation connection, insertion length, and sensor construction suit the vessel design.
Application suitability must be evaluated against the actual process conditions and confirmed product ratings.
Integrated Pt100 and Transmitter: Combines temperature sensing and signal conversion in one assembly, simplifying the interface with compatible control systems.
4–20 mA Output: Provides a standard analog signal for industrial monitoring and control applications.
Mineral-Insulated RTD Probe: Offers a compact, sheathed sensing structure for industrial installation.
Threaded Process Connection: Supports installation where the specified threaded interface is compatible with the equipment.
Optional HART Communication: Available only when confirmed for the selected transmitter configuration.
Stainless Steel Protection Components: The listed configuration uses SS316L for the protection tube and SS304 for the separate thermowell; confirm material compatibility for the application.
Configuration-Based Selection: Measuring range, probe dimensions, wiring, output options, and enclosure protection can be selected from confirmed product configurations.
Parameter | Specification |
|---|---|
Product Type | Integrated Pt100 RTD Temperature Transmitter |
Model | SBWZ Series |
Sensor Type | Pt100 RTD |
RTD Element Configuration | Single Element / Dual Element Optional |
RTD Wiring | 3-wire standard; 2-wire / 4-wire optional |
Transmitter Type | Head-mounted temperature transmitter |
Input Signal | Pt100 resistance signal |
Output Signal | 4–20 mA DC, two-wire |
Power Supply | 12–36 VDC |
Communication | HART optional |
Measuring Range | 0–100°C, customizable |
Sensor Accuracy Class | Class A / Class B optional |
Probe Type | Mineral-insulated RTD probe |
MI Probe Diameter | Φ6 mm |
Protection Tube | Φ12 mm OD × 2 mm wall thickness |
Protection Tube Material | SS316L |
Thermowell Material | SS304 |
Thermowell Length | H = 50 mm |
Thermowell Inner Diameter | Φ14 mm |
Thermowell Bottom Step OD | Φ20 mm |
Overall Length | 250 mm |
Insertion Length | 100 mm |
Process Connection | M20 × 1.5 thread with sealing step |
Gasket Material | PTFE |
Terminal Box Material | Aluminum alloy |
Ingress Protection | IP65 standard / IP67 optional |
Specifications can be customized according to customer requirements.
Measuring Range: Confirm the required operating temperature and available transmitter range.
RTD Element: Confirm single or dual element configuration.
Wiring: Select a supported 2-wire, 3-wire, or 4-wire RTD arrangement.
Output Signal: Confirm 4–20 mA output and any approved alternative configuration.
Communication: Specify HART only if supported by the selected transmitter.
Probe Dimensions: Confirm probe diameter, insertion length, and overall assembly dimensions.
Protection Components: Select the confirmed protection tube and thermowell materials based on process compatibility.
Process Connection: Specify the thread type, dimensions, and sealing arrangement.
Enclosure Protection: Confirm the required IP rating and available terminal-box configuration.
Nonstandard configurations are subject to engineering evaluation and manufacturing confirmation.
Provide the normal operating temperature, minimum and maximum temperatures, and any relevant temperature fluctuations.
Determine whether the receiving system requires a 4–20 mA signal and whether HART communication is necessary.
Confirm Pt100 element requirements, wiring arrangement, and the required sensor tolerance class.
Provide the required insertion length, probe diameter, installation depth, and thermowell dimensions. Confirm that the measuring assembly fits the protection structure.
Specify the thread dimensions, sealing method, and mounting requirements. Do not assume M20 × 1.5 is compatible with other thread standards.
Provide the process medium and operating conditions to help determine whether the specified stainless steel components and seals are suitable.
Specify the power supply, terminal-box requirements, ambient conditions, and required ingress protection rating.
A Pt100 is a resistance temperature sensing element. An integrated temperature transmitter also contains electronics that convert the sensor signal into a standardized output, such as 4–20 mA.
The listed SBWZ configuration uses a two-wire 4–20 mA output. Confirm the required measuring range and transmitter configuration before ordering.
HART is listed as an optional function. Confirm its availability for the selected model and output configuration.
A mineral-insulated probe uses a metal sheath and compact internal construction to protect the sensing element. Its actual temperature, pressure, and mechanical limits depend on the selected design.
A thermowell can provide additional mechanical protection and a defined process interface. Confirm its dimensions, material, and compatibility with the sensor assembly.
Provide the required measuring range, output signal, HART requirement, RTD wiring, probe dimensions, process connection, process medium, operating conditions, ingress protection requirement, and quantity.
Please send JIECHUANG your required measuring range, output signal, communication requirements, probe dimensions, process connection, and operating conditions.
If available, include an installation drawing, existing instrument nameplate, or technical datasheet. Our team can review the requirements and confirm the suitable configuration before quotation.
Contact JIECHUANG for technical selection and pricing information.