| Availability: | |
|---|---|
| Quantity: | |
JC-SBWZ Series
Jiechuang
The JC-SBWZ Series Explosion Proof Pt100 Temperature Transmitter is an integrated industrial temperature measurement device with a local LCD display, Pt100 RTD sensor and built-in temperature transmitter.
The Pt100 Class A sensing element measures the process temperature, while the transmitter converts the signal into a standard 4-20mA output with HART communication for connection to PLC, DCS and other industrial control systems.
The transmitter is housed in a flameproof Ex db IIC T6 Gb enclosure for industrial hazardous-area applications.
The sensing assembly uses a Φ8 × 0.9 mm 316 stainless steel protection tube with an internal Φ5 mm mineral-insulated (MI) armored core.
A 1/2" NPT adjustable compression fitting allows the insertion position to be adjusted during installation.
The local LCD display provides convenient on-site temperature reading while the 4-20mA + HART signal supports remote monitoring and configuration.
Process pipeline temperature monitoring
Temperature measurement on compatible process equipment
Industrial gas system monitoring
Temperature measurement in process pipelines
Chemical equipment temperature monitoring
Temperature monitoring in suitable storage and process systems
Auxiliary system temperature measurement
Industrial heating equipment monitoring
Temperature monitoring on compatible plant equipment
Temperature monitoring on pumps and compressors
Process equipment temperature measurement
Local indication and remote signal transmission to a control system
The Ex db protection concept is commonly used for flameproof equipment in hazardous gas areas such as Zone 1 and Zone 2, subject to the applicable certification and installation requirements.
Pt100 RTD Sensor: Uses a platinum resistance sensor for industrial temperature measurement.
Class A Sensor: The listed sensing element is Pt100 Class A. Confirm the required measurement range and accuracy for the application.
4–20mA + HART Output: Supports analog temperature transmission and HART communication with compatible control systems.
Local LCD Display: Allows operators to read temperature values at the installation point.
Integrated Construction: Combines the sensor, transmitter and display in one field-mounted instrument.
316 Stainless Steel Protection Tube: The listed Φ8 × 0.9 mm tube provides mechanical protection for the sensing assembly.
Mineral-Insulated Sensing Core: Uses a listed Φ5 mm MI core.
Adjustable Threaded Installation: Allows insertion position adjustment within the confirmed mechanical limits.
Explosion-Proof Configuration: Ex db IIC T6 Gb housing for industrial hazardous-area temperature measurement.
Item | Specification |
|---|---|
Product Type | Explosion Proof Integrated Temperature Transmitter |
Model | JC-SBWZ Series |
Temperature Sensor | Pt100 RTD |
Accuracy Class | Class A |
Measuring Range | -40 to +120°C |
Transmitter Accuracy | ±0.5% FS |
Display | Local LCD Display |
Output Signal | 4-20mA + HART |
Power Supply | 24VDC |
Explosion-Proof Rating | Ex db IIC T6 Gb |
Protection Tube Diameter | Φ8 mm |
Protection Tube Wall Thickness | 0.9 mm |
Protection Tube Material | 316 Stainless Steel |
Internal Core | Φ5 mm Mineral Insulated (MI) Armored Core |
Process Connection | 1/2" NPT Adjustable Compression Fitting |
Compression Fitting Material | SS304 |
Upper Adapter Thread | M27 × 2 |
Electrical Connection | 1/2" NPT |
Protection Tube Length | 200 mm |
Nominal Insertion Length | 50 mm |
Adjustable Insertion Range | 0-150 mm |
Installation | Adjustable Threaded Installation |
Sensor/Transmitter Construction | Integrated |
Customization | Available |
Note: Specifications can be customized according to customer requirements.
Step 1 — Specify the temperature range.
Provide the minimum, normal and maximum process temperatures. Confirm that the sensor and transmitter are suitable for the required operating range.
Step 2 — Select the sensor.
Specify Pt100 and the required sensor accuracy class. If a different sensor or wiring arrangement is needed, confirm availability before ordering.
Step 3 — Confirm the installation dimensions.
Provide the required protection tube length, insertion length and adjustment range. Confirm the reference point used for each dimension.
Step 4 — Confirm the connection.
Specify the process fitting thread and electrical connection separately. Provide the applicable thread standard and size to avoid installation mismatch.
Step 5 — Define the signal interface.
Confirm 4–20mA output, HART communication, power supply and compatibility with the receiving control system.
Step 6 — Confirm site safety requirements.
Provide the hazardous-area classification and required certification. Ensure that the complete instrument configuration is suitable for the installation location.
A: It measures process temperature using a Pt100 RTD sensor and converts the sensor signal into a standard output for monitoring and control.
A: Yes. The listed configuration includes an LCD display for local temperature indication.
A: The listed output is 4–20mA with HART communication. Confirm the required interface and power supply when ordering.
A: Pt100 Class A describes the sensor accuracy class. Transmitter accuracy describes the performance of the signal-conversion electronics. They are separate specifications and should be checked independently.
A: The product information lists an adjustable insertion range of 0–150 mm and a nominal insertion length of 50 mm. Confirm the dimensional reference and available adjustment range for the selected configuration.
A: The listed explosion-protection marking is Ex db IIC T6 Gb. Confirm the applicable certificate, equipment marking and installation requirements before use in a hazardous area.
A: Please provide the temperature range, sensor type, output signal, process connection, electrical connection, protection tube length, required insertion length, power supply and hazardous-area requirements.
For an accurate quotation, please provide:
Required temperature range
Pt100 sensor accuracy class
Output signal and HART requirement
Power supply
Process connection and electrical connection
Protection tube diameter, material and length
Required insertion length and adjustment range
Hazardous-area classification and certification requirements
Order quantity
JIECHUANG can review the application requirements and confirm the suitable configuration, available options and quotation details.