| Availability: | |
|---|---|
| Quantity: | |
JC-LG
Jiechuang
The JC-LG Series Orifice Plate is a primary flow measurement element designed for differential pressure flow measurement of liquids, gases and steam.
When fluid passes through the orifice, its velocity and pressure change, creating a differential pressure between the upstream and downstream sides. The flow rate can be calculated from this differential pressure together with the relevant process data and flow calculation parameters.
Manufactured from stainless steel, the orifice plate can be configured for different pipeline sizes, pressure ratings, pressure tapping methods and process conditions.
A compatible differential pressure transmitter and suitable flow calculation setup can be selected when required.
The JC-LG orifice plate can be used in differential pressure flow measurement systems for:
Water treatment and water supply
Chemical processing
Oil and gas processing
Petrochemical pipelines
Power plants
Boiler steam systems
Compressed air systems
Natural gas pipelines
HVAC and industrial process systems
Uses the pressure difference generated across the orifice to support flow rate calculation.
Available in SS304, SS316 or SS316L, subject to the selected configuration and process medium.
Nominal sizes from DN15 to DN1000 are listed as customizable options, subject to design and availability.
Flange tap, corner tap and D-D/2 tap configurations can be selected according to the required design.
The orifice plate has no moving mechanical components, helping simplify routine maintenance.
Flange specifications and connection standards can be selected to match compatible pipeline designs.
A differential pressure transmitter and valve manifold can be specified separately or as part of a confirmed assembly.
Item | Specification |
|---|---|
Product Name | Flange Mounted Orifice Plate Throttling Device |
Measuring Principle | Differential Pressure Measurement |
Type | Orifice Plate Flow Measurement Element |
Material | Stainless Steel 304 / Stainless Steel 316 / 316L |
Structure | Flange Mounted Type |
Application Medium | Liquid, Gas, Steam |
Nominal Size | DN15 ~ DN1000 (Customized) |
Pressure Rating | PN10 / PN16 / PN25 / PN40 / ANSI Class 150~600 (Customized) |
Pressure Tapping Method | Flange Tap / Corner Tap / D-D/2 Tap |
Accuracy | ±0.5% ~ ±1.5% (Depending on design conditions) |
Installation | Between Pipeline Flanges |
Connection Standard | DIN / ANSI / JIS / GB Standard |
Working Temperature | Customized according to material and application |
Working Pressure | According to flange pressure rating |
Optional Accessories | Differential Pressure Transmitter, Valve Manifold |
Note: Specifications can be customized according to customer requirements.
The following options can be discussed during technical selection, subject to product availability:
Material: SS304 / SS316 / SS316L
Nominal Size: DN15–DN1000, subject to design
Pressure Rating: PN or ANSI Class options, according to the required standard
Pressure Tapping: Flange tap / corner tap / D-D/2 tap
Connection Standard: DIN / ANSI / JIS / GB
Optional Accessories: Differential pressure transmitter and valve manifold
Please confirm the required combination before ordering.
To select a suitable orifice plate, please provide:
Fluid: Liquid, gas or steam, including the medium name.
Flow Range: Minimum, normal and maximum flow rates.
Pipeline Size: Nominal diameter and actual pipe specifications.
Operating Conditions: Pressure and temperature.
Pressure Rating: Required flange standard and pressure rating.
Material: Required material based on fluid compatibility.
Pressure Tapping: Preferred tapping method, if specified.
Output and Accessories: Whether a differential pressure transmitter or valve manifold is required.
These details help determine the suitable orifice design and the parameters needed for flow calculation.
It creates a differential pressure that can be used to calculate fluid flow rate.
Yes. The design must be selected for the specific medium and operating conditions.
Not necessarily. A differential pressure transmitter can be selected separately or included in a confirmed assembly.
Yes. Size and material options depend on the required design and operating conditions.
Please provide the fluid, flow range, pipe size, pressure, temperature, material and quantity.
Fluid type and name
Minimum, normal and maximum flow rates
Pipeline size
Operating pressure and temperature
Required material
Flange standard and pressure rating
Quantity
Pressure tapping method
Differential pressure transmitter
Valve manifold
Special dimensions or installation conditions
JIECHUANG can review your process data and confirm a suitable orifice plate configuration for your application.