| Availability: | |
|---|---|
| Quantity: | |
JC-56UB
JIECHUANG
The JC-56UB Magnetic Float Level Transmitter is designed for continuous liquid level measurement in tanks and vessels. It uses a float and sensing probe to detect changes in liquid level and converts the level signal into a standard 4–20 mA output for remote monitoring and control.
The transmitter is installed vertically from the top of the tank through a DN80 PN16 RF flange. Its stainless steel probe and flange construction are suitable for general industrial liquid level measurement. An explosion-proof version is available for applicable hazardous-area installations.
The measuring range, probe length, process connection, and other parameters can be customized according to tank dimensions and application requirements.
Continuous liquid level monitoring for water storage and wastewater treatment tanks.
Suitable for liquid level monitoring in oil, fuel, and hydraulic oil storage tanks.
Used for compatible chemical liquids where the standard SS304 wetted construction is suitable.
Provides continuous level information for process tanks and vessels.
Suitable for liquid storage and monitoring applications in industrial utility systems.
The transmitter is installed vertically through the tank top, making it suitable for vessels where side-mounted installation is not preferred.
Provides continuous level measurement for tanks and process vessels rather than simple point-level switching.
A float follows liquid level changes along the sensing probe, allowing the transmitter to determine the liquid level.
The 4–20 mA signal can be used for remote monitoring and integration with industrial control systems.
The standard probe and flange are made of SS304 for general industrial liquid level applications.
The measuring range and probe length can be customized according to tank dimensions.
An Ex db IIC T6 Gb version is available for applicable hazardous-area requirements.
Parameter | Specification |
|---|---|
Product Model | JC-56UB |
Product Type | Magnetic Float Level Transmitter |
Installation | Top Mounted / Top Insertion |
Measuring Range | 0–1300 mm, Customizable |
Probe Length | 1400 mm, Customizable |
Probe Diameter | Φ20 mm |
Accuracy | ±10 mm |
Process Connection | Flange |
Flange Size | DN80 |
Flange Rating | PN16 |
Flange Face | RF, Raised Face |
Flange Material | SS304 |
Probe Material | SS304 |
Output Signal | 4–20 mA |
Power Supply | 24 VDC |
Max. Working Pressure | ≤1.6 MPa |
Min. Medium Density | ≥0.5 g/cm³ |
Medium Temperature | -20 to +120°C |
Explosion-Proof | Ex db IIC T6 Gb |
Protection Rating | IP65 / IP67 Optional |
Installation Direction | Vertical |
Note: Specifications can be customized according to customer requirements.
The JC-56UB can be configured according to application requirements.
Available customization includes:
Measuring range
Probe length
Process connection
Flange configuration
Protection rating
Explosion-proof configuration
Special configurations are subject to engineering confirmation.
For accurate model selection and quotation, please provide:
Tank height
Required measuring range
Installation position
Liquid type
Minimum medium density
Corrosiveness
Operating pressure
Medium temperature
Flange size
Pressure rating
Flange facing
Output signal
Power supply
Hazardous-area requirements
Yes. The JC-56UB is designed for vertical top-mounted/top-insertion installation through a tank flange.
It is a continuous liquid level transmitter. The level signal is converted into a 4–20 mA output for remote monitoring and control.
The listed standard configuration has a measuring range of 0–1300 mm with a 1400 mm probe length. The range and probe length can be customized.
The standard configuration uses a DN80 PN16 RF flange made of SS304.
The standard output is 4–20 mA, with a 24 VDC power supply.
An Ex db IIC T6 Gb explosion-proof version is listed. The exact certification and suitability should be confirmed according to the installation area and project requirements.
Please provide the following information for accurate selection and quotation:
Measuring range
Probe length
Tank height
Medium and density
Process temperature
Operating pressure
Flange size and rating
Output requirement
Hazardous-area requirement